• ID Code: K5-34
  • Purpose: Show that the resistance of copper changes linearly with temperature.
  • Description: Measure the resistance of the copper coil at room temperature (295K), at the temperature of a dry ice and methanol mixture (195K), and at the temperature of liquid nitrogen (77K). Plot resistance versus temperature to demonstrate the linearity.
  • Availability: Limited Availability - Please contact LecDem via email several days in advance to confirm materials
  • References: http://lecdem.physics.umd.edu/images/refs/refsk.htm#K5-34
  • Loc codes: K5, I0, ME2