K8-32: PULSES IN TRANSMISSION LINES

More
12 years 2 days ago - 11 years 11 months ago #692 by zzfixk21
K8-32: PULSES IN TRANSMISSION LINES was created by zzfixk21






ID Code: K8-32
Purpose: Demonstrate the reflection of pulses in terminated and unterminated transmission lines and to determine the speed of an electromagnetic wave in the transmission line.
Description: An oscillator produces pulses at a rate of about 100 khz, which are input into the transmission line. The scope is triggered on the initial pulse, and the pulse is displayed on the top trace of the dual trace scope as it enters the transmission line and as it returns. The pulse at the end of the transmission line is displayed on the bottom trace. For a short section of transmission line the input and output pulses almost line up. Using about 100 feet of transmission line the delay is approximately 150 ns; for this cable v/c is approximately 0.67 so the wave time is about 1.5 nanosecond per foot.

To see reflections, use only the top trace. The far end can be left open, shorted, or terminated with a 50 ohm terminator to prevent reflection, as shown in the center two photographs above. The photographs below these two show the oscilloscope showing the 10 MHz pulse train (left), reflections with the far end of the cable connected to the lower trace of the oscilloscope, with the horizontal scale 250 nanoseconds per division (left center) and 100 nanosecond per division (center), the far end terminated by 50 ohms (right center), and the far end shorted but not connected to the oscilloscope (right).

Availability: Available
Last edit: 11 years 11 months ago by zzfixk21.

Please Log in to join the conversation.